Quality Substrate Material 

Our tubular anode is manufactured from high-tensile seamless titanium tube, which meets ASTM B338 Grade 1 standards. 


Element

Grade I

Grade II

Iron (Fe)
0.20% max.
0.30% max.
Carbon (C)
0.08% max.
0.08% max.
Nitrogen (N)
0.03% max.
0.03% max.
Hydrogen (H)
0.015% max.
0.015% max.
Oxygen (O)
0.18% max.
0.25% max.
Single Impurity (Each)
0.10% max.
0.10% max.
Other Impurities (Total)
0.40% max.
0.40% max.
Titanium (Ti)
Remainder
Remainder


Noble Metal Oxide Coating 

The Ir–Ta (IrO2/Ta2O5) mixed metal oxide catalyst sintered to the surface of titanium substrate demonstrates high chemical stability when subject to high current density. We can produce anodes with differing coating thickness and noble metal oxide ratios upon request. Strict quality control procedures are followed throughout the coating process to ensure appropriate coating thickness and adhesion. Based upon accelerated life testing, conducted by an independent laboratory, our MMO coating has been proven to have an increased life expectancy when compared with other similar products on the market. 


 Ir–Ta Mixed Metal Oxide Catalyst

The iridium-tantalum mixed metal oxide catalyst is recommended for use in soil or fresh water, where there is either no
chloride ions or low chloride ions present.


Technical Measurement

Performance

Coating Element IrO2, Ta2O5
Coating Thickness
5~10 μm
Coating Uniformity
85% min.
Working Environment
Fine sand, Coke Breeze, Freshwater


 Ir–Ru Mixed Metal Oxide Catalyst

The iridium-ruthenium mixed metal oxide catalyst can be used in seawater, brackish water, mud, concrete and any other severe environment conditions including high acidity or in the presence of chlorine or oxygen.


Technical Measurement

Performance

Coating Element IrO2, RuO2
Coating Thickness
5~10 μm
Coating Uniformity
85% min.
Working Environment
Mud, Concrete, Seawater

* We can produce anodes with different nobel metal oxide ratios and differing coating thickness as specific required.


Low Electrical Resistance 

The anode has an extremely low consumption rate, measured in milligrams per ampere-year. The dimensions remain nearly unchanged throughout the design life of the anode, providing a consistently low resistance. 


Wide Cable Selection 

PVDF, HMWPE, HALAR, XLPE, PVC or KYNAR are all optional. We recommend dual-insulated cable(such as PVDF/HMWPE) for use in ground beds with high chloride concentration. While HMWPE is an economical choice for shallow vertical and horizontal surface beds with no chlorides.